by gdnadmin · April 8, 2019
Uplink failure alarm can be configure in case of any Uplink failure. Alarm will be triggers and Alarm_Out_NO Relay will Close.
in this example we are configuring failure ditection in case on uplink port GigabitEthernet1/1 or GigabitEthernet1/2 Fails
!
alarm profile OPEN
alarm link-fault not-forwarding not-operating
syslog not-operating
notifies not-operating
relay-major link-fault not-forwarding not-operating
!
!Apply following command only on IE switch Uplinks
!
interface GigabitEthernet1/1
alarm profile OPEN
!
interface GigabitEthernet1/2
alarm profile OPEN
do wr
!